Blueprint: The Manufacturing Predictor
Operational Tool Gating for IoT-Driven Agents
Industrial AI agents used in manufacturing use IoT sensor data to predict machine failures and autonomously adjust production lines. Governance is critical here: an agent should not be able to "shut down" a furnace without proper authorization or specific identity verification.
Roadmap: HITL approval workflows are planned for a future release. Current policies support allow/deny/warn/audit effects only. The deny-based gating shown below enforces operational safety without requiring manual approval steps.
This blueprint demonstrates Context-Aware Operational Gating.
Architecture
1. Master Policy Definition
Define strict operational safety rules for industrial tools.
{
"name": "industrial-safety-policy",
"priority": 9500,
"rules": [
{
"id": "require-maintenance-mode",
"effect": "deny",
"principals": ["agent:maintenance-bot"],
"actions": ["iot:shutdown_machine"],
"resources": ["*"],
"conditions": {
"maintenance_mode": "false"
}
},
{
"id": "allow-iot-read",
"effect": "allow",
"principals": ["*"],
"actions": ["iot:read_sensor"],
"resources": ["*"]
}
]
}
2. Implementation
Python IoT Prototype
import requests
from openai import OpenAI
client = OpenAI(
api_key="ignored",
base_url="http://cz-gateway:8001/v1",
default_headers={
"X-ControlZero-Agent-ID": "maintenance-bot",
"X-ControlZero-Maintenance-Mode": "false" # Dynamic state
}
)
def handle_sensor_alert(machine_id: str, temperature: float):
print(f"Alert: Machine {machine_id} at {temperature}C")
# Policy Enforcement happens at the Gateway
try:
response = client.chat.completions.create(
model="gpt-4o-mini",
messages=[{"role": "user", "content": f"Machine {machine_id} is overheating. Should I shut it down?"}],
tools=[{
"type": "function",
"function": {
"name": "iot:shutdown_machine",
"parameters": {"type": "object", "properties": {"machine_id": {"type": "string"}}}
}
}]
)
return response
except Exception as e:
return f"Operational Safety Block: {e}"
# Scenario A: Shutdown attempt while NOT in maintenance mode
print(handle_sensor_alert("furnace-01", 1200.5))
# RESULT: BLOCKED
3. Validation Checklist
- State-Based Gating: Verify that switching
X-ControlZero-Maintenance-Modetotrueallows the shutdown command to proceed. - High-Availability Check: Ensure the Control Zero Gateway is deployed in HA mode to prevent governance-induced downtime.
- Audit Compliance: Verify that all industrial tool calls are logged with sensor context for regulatory safety reviews.